Cat's Whisker
Science & astronomy Allocation

Millimetre-wave plasma diagnostics (interferometry and reflectometry)

100–300 GHz
200 GHz wide · Extremely high frequency
Modes
CW, FMCW
Allocation
Primary
Region
Worldwide
Service
Fusion plasma measurement
Licence
Scientific installation, radiation confined to vessel
Power
Milliwatts
Confidence
Medium
Importance
●●○○○

Fusion machines probe their own plasmas with low-power millimetre waves swept across this entire range.

Alongside the megawatt heating gyrotrons, every tokamak and stellarator carries a suite of milliwatt diagnostic sources across 100-300 GHz. Interferometers measure the line-integrated electron density from the phase shift a beam accumulates crossing the plasma. Reflectometers sweep frequency and time the echo from the layer where the plasma's cutoff frequency matches the probe, mapping the density profile. Electron cyclotron emission receivers work passively, reading the plasma's own thermal emission at the cyclotron harmonics to get an electron temperature profile with millisecond resolution. All of it happens inside a grounded vessel and never reaches the outside spectrum.

Inside this band

Part of

Nearby

Sources