Cat's Whisker
Industrial Allocation

Hot-electron bolometer (HEB) mixers - heterodyne detection above the superconducting gap

0.3–3 THz
2.7 THz wide · Tremendously high frequency
Modes
Heterodyne receive
Allocation
Secondary
Region
Worldwide
Service
Detector technology
Licence
Receive only
Importance
●●○○○

The only heterodyne detector that works above about 1.3 THz - a superconducting nanobridge whose electron temperature, not its quasiparticle tunnelling, does the mixing.

SIS mixers are near-quantum-limited but stop working above the superconducting energy gap, roughly 700 GHz for niobium and 1.2-1.3 THz for NbTiN. Above that the standard is the hot-electron bolometer: a nanoscale NbN or NbTiN bridge in which the local oscillator heats the electron gas, and the resistance change follows the beat frequency. HEBs are perhaps ten times less sensitive than SIS mixers but have no upper frequency limit and need only microwatts of local-oscillator power - which matters when your LO is a quantum cascade laser. Every terahertz heterodyne receiver above 1.3 THz ever flown, on Herschel, SOFIA, STO-2 and GUSTO, uses HEB mixers.

Inside this band

Part of

Nearby

Sources