Terahertz imaging in art conservation and cultural heritage
- Modes
- Pulsed reflection imaging
- Allocation
- Secondary
- Region
- Worldwide
- Service
- Non-destructive examination
- Licence
- None
- Power
- Microwatts
- Confidence
- Medium
- Importance
- ●○○○○
Terahertz pulses penetrate paint, plaster and wood without ionising anything, revealing underdrawings, hidden layers and structural damage in artworks.
X-rays reveal heavy pigments and infrared reflectography reveals carbon underdrawing, but neither gives depth information. A terahertz pulse returns a separate echo from each interface, so a scan produces a genuine layer-by-layer cross section of a painting or a fresco - ground, underdrawing, paint layers, varnish, and any earlier composition beneath. It has been used on Renaissance panel paintings, on wall paintings, on mummy wrappings and on historical instruments. The radiation is non-ionising and the power is microwatts, so there is no conservation risk. This is a small field but a completely uncontroversial and real use of spectrum with no allocation.
Inside this band
- 300 GHz300 GHz - the canonical terahertz communications carrier
- 300–312.96 GHzIEEE 802.15.3d 2.16 GHz base channels above 300 GHz
- 300–450 GHzTerahertz wireless data centre and kiosk downloading use cases
- 0.3–1 THzGyrotrons in the sub-terahertz and terahertz range
- 0.3–1 THzTerahertz non-destructive testing - coating and paint thickness measurement
- 0.3–1 THzTerahertz security screening - passive and active imaging of concealed objects
- 0.3–1.2 THzSIS mixers - quantum-limited heterodyne detection below the superconducting gap
- 0.3–1.5 THzSchottky diode frequency multiplier chains
- 0.3–1.5 THzBackward wave oscillators (BWO) as tunable terahertz sources
- 0.3–1.5 THzResonant tunnelling diode (RTD) terahertz oscillators
- 0.3–1.5 THzTerahertz industrial process monitoring - moisture, plastics, paper and composites
- 306–313 GHz306-313 GHz land mobile and fixed identification (WRC-19, RR 5.564A)
- 313–318 GHz313-318 GHz passive-protected gap (Resolution 731 conditions apply)
- 313–356 GHzEESS/SRS passive identification 313-356 GHz (RR 5.565)
- 315–375 GHz850 micron atmospheric windowHigh dry sites: Chajnantor, Maunakea, South Pole
- 318–333 GHz318-333 GHz land mobile and fixed identification (WRC-19, RR 5.564A)
- 325.1529 GHzAtmospheric water-vapour absorption line, 325.153 GHz
- 327–371 GHzRadio astronomy identification 327-371 GHz (RR 5.565)
- 333–356 GHz333-356 GHz passive-protected gap (Resolution 731 conditions apply)
- 342.88285 GHzCS J=7-6 rest frequency 342.88285 GHz
- 345 GHzEvent Horizon Telescope 345 GHz observing bandGlobal VLBI array: Chile, Hawaii, Spain, Mexico, Arizona, Greenland, South Pole
- 0.345–2.985 THzThe CO rotational ladder (J=3-2 upward) - the thermometer of molecular gas
- 345.79599 GHzCO J=3-2 rest frequency 345.79599 GHz
- 353–666 GHzJCMT SCUBA-2 - simultaneous 850 and 450 micron continuum cameraJames Clerk Maxwell Telescope, Maunakea, Hawaii (4092 m)
- 354.50548 GHzHCN J=4-3 rest frequency 354.50548 GHz
- 356–450 GHz356-450 GHz land mobile and fixed identification (WRC-19, RR 5.564A)
- 356.73424 GHzHCO+ J=4-3 rest frequency 356.73424 GHz
- 361–365 GHzEESS/SRS passive identification 361-365 GHz (RR 5.565)
- 369–392 GHzEESS/SRS passive identification 369-392 GHz (RR 5.565)
- 372.42134 GHzortho-H2D+ ground-state line, 372.42134 GHz
- 372.67249 GHzN2H+ J=4-3 rest frequency 372.67249 GHz
- 380.1974 GHzAtmospheric water-vapour absorption line, 380.197 GHz
- 385–500 GHzALMA Band 8 (385-500 GHz, 0.6-0.8 mm)Llano de Chajnantor, Chile (5058 m)
- 388–424 GHzRadio astronomy identification 388-424 GHz (RR 5.565)
- 397–399 GHzEESS/SRS passive identification 397-399 GHz (RR 5.565)
- 409–411 GHzEESS/SRS passive identification 409-411 GHz (RR 5.565)
- 416–434 GHzEESS/SRS passive identification 416-434 GHz (RR 5.565)
- 424.763 GHzAtmospheric molecular oxygen absorption line, 424.763 GHz
- 426–442 GHzRadio astronomy identification 426-442 GHz (RR 5.565)
- 430–500 GHz650 micron atmospheric windowHigh dry sites
- 439–467 GHzEESS/SRS passive identification 439-467 GHz (RR 5.565)
- 0.447–1.546 THzHerschel SPIRE Fourier transform spectrometer (447-1546 GHz)ESA Herschel Space Observatory (2009-2013)
- 448.001 GHzAtmospheric water-vapour absorption line, 448.001 GHz
- 453–510 GHzRadio astronomy identification 453-510 GHz (RR 5.565)
- 461.040768 GHzCO J=4-3 rest frequency 461.04077 GHz
- 477–502 GHzEESS/SRS passive identification 477-502 GHz (RR 5.565)
- 0.48–1.91 THzHerschel HIFI - Heterodyne Instrument for the Far Infrared (480-1250 and 1410-1910 GHz)ESA Herschel Space Observatory, Sun-Earth L2 (2009-2013)
- 487.2494 GHzAtmospheric molecular oxygen absorption line, 487.249 GHz
- 0.49–3 THzSOFIA GREAT and upGREAT heterodyne receivers (0.49-5.4 THz, portion below 3 THz)NASA/DLR SOFIA, Boeing 747SP at 12-14 km (2010-2022)
- 492.16065 GHz[C I] 609 micron neutral carbon line, 492.16065 GHz
- 523–527 GHzEESS/SRS passive identification 523-527 GHz (RR 5.565)
- 538–581 GHzEESS/SRS passive identification 538-581 GHz (RR 5.565)
- 556.93599 GHzOrtho-water ground-state line, 556.93599 GHz
- 576.267931 GHzCO J=5-4 rest frequency 576.26793 GHz
- 602–720 GHzALMA Band 9 (602-720 GHz, 0.4-0.5 mm)Llano de Chajnantor, Chile (5058 m)
- 611–630 GHzEESS/SRS passive identification 611-630 GHz (RR 5.565)
- 620.7 GHzAtmospheric water-vapour absorption line, 620.700 GHz
- 623–711 GHzRadio astronomy identification 623-711 GHz (RR 5.565)
- 624.32–650.32 GHzJEM/SMILES superconducting submillimetre limb sounder (624-650 GHz)Japanese Experiment Module, International Space Station (2009-2010)
- 630–710 GHz450 micron atmospheric windowChajnantor, Maunakea, South Pole
- 634–654 GHzEESS/SRS passive identification 634-654 GHz (RR 5.565)
- 657–692 GHzEESS/SRS passive identification 657-692 GHz (RR 5.565)
- 691.473076 GHzCO J=6-5 rest frequency 691.47308 GHz
- 713–718 GHzEESS/SRS passive identification 713-718 GHz (RR 5.565)
- 729–733 GHzEESS/SRS passive identification 729-733 GHz (RR 5.565)
- 750–754 GHzEESS/SRS passive identification 750-754 GHz (RR 5.565)
- 752.033 GHzAtmospheric water-vapour absorption line, 752.033 GHz
- 771–776 GHzEESS/SRS passive identification 771-776 GHz (RR 5.565)
- 773.84 GHzAtmospheric molecular oxygen absorption line, 773.840 GHz
- 787–950 GHzALMA Band 10 (787-950 GHz, 0.3-0.4 mm)Llano de Chajnantor, Chile (5058 m)
- 790–950 GHz350 micron atmospheric windowChajnantor (5000 m+), South Pole, Dome A
- 795–909 GHzRadio astronomy identification 795-909 GHz (RR 5.565)
- 806.651806 GHzCO J=7-6 rest frequency 806.65181 GHz
- 809.34197 GHz[C I] 370 micron neutral carbon line, 809.34197 GHz
- 823–846 GHzEESS/SRS passive identification 823-846 GHz (RR 5.565)
- 850–854 GHzEESS/SRS passive identification 850-854 GHz (RR 5.565)
- 857–862 GHzEESS/SRS passive identification 857-862 GHz (RR 5.565)
- 866–882 GHzEESS/SRS passive identification 866-882 GHz (RR 5.565)
- 905–928 GHzEESS/SRS passive identification 905-928 GHz (RR 5.565)
- 916.1716 GHzAtmospheric water-vapour absorption line, 916.172 GHz
- 921.7997 GHzCO J=8-7 rest frequency 921.79970 GHz
- 926–945 GHzRadio astronomy identification 926-945 GHz (RR 5.565)
- 951–956 GHzEESS/SRS passive identification 951-956 GHz (RR 5.565)
- 968–973 GHzEESS/SRS passive identification 968-973 GHz (RR 5.565)
- 985–990 GHzEESS/SRS passive identification 985-990 GHz (RR 5.565)
- 987.92676 GHzPara-water 2(0,2)-1(1,1) line, 987.92676 GHz
- 1–3 THz1-3 THz - the completely unregulated decade
- 1.036912 THzCO J=9-8 rest frequency 1036.91239 GHz
- 1.113343 THzPara-water ground-state line, 1113.34301 GHz
- 1.151985 THzCO J=10-9 rest frequency 1151.98545 GHz
- 1.2–3 THzTerahertz quantum cascade lasers (1.2-5 THz, portion below 3 THz)
- 1.232476 THzHF J=1-0 rest frequency 1232.4763 GHz
- 1.3–1.6 THzAntarctic terahertz windows (200 micron / 1.3-1.5 THz)Dome A and South Pole, Antarctica
- 1.381995 THzCO J=12-11 rest frequency 1381.99510 GHz
- 1.4–1.9006 THzGUSTO balloon-borne terahertz spectrometer ([N II] 1.46 THz and [C II] 1.90 THz)NASA long-duration balloon, Antarctica, ~36 km altitude (launched Dec 2023)
- 1.43–3 THzHerschel PACS spectrometer coverage in the 1.4-3 THz range (57-210 micron band)ESA Herschel Space Observatory (2009-2013)
- 1.461134 THz[N II] 205 micron fine-structure line, 1461.134 GHz
- 1.669905 THzOrtho-water 2(1,2)-1(0,1) line, 1669.90478 GHz
- 1.8347 THzOH 163 micron rotational transition near 1834.7 GHz
- 1.841346 THzCO J=16-15 rest frequency 1841.34551 GHz
- 1.900537 THz[C II] 158 micron fine-structure line, 1900.5369 GHz
- 2.01 THzHeH+ J=1-0 rotational line near 2.010 THz - the first molecule in the universe
- 2.060069 THz[O I] 145 micron fine-structure line, 2060.07 GHz
- 2.45938 THz[N II] 122 micron fine-structure line, 2459.38 GHz
- 2.5099–2.5143 THzAura MLS 2.5 THz radiometer - hydroxyl radical measurement from orbitNASA Aura spacecraft, 705 km sun-synchronous orbit
- 2.5143 THzOH 119 micron rotational transition near 2514.3 GHz
- 2.52278 THzMethanol far-infrared gas laser line at 2.5228 THz (119 micron)
- 2.674986 THzHD J=1-0 rest frequency 2674.99 GHz (112 micron)
Part of
- 0.3–3 THzAtmospheric attenuation across the terahertz range (ITU-R P.676)
- 0.3–3 THzTerahertz time-domain spectroscopy (THz-TDS), 0.1-10 THz
- 0.3–3 THzThe terahertz gap - the technology gap that named the band
- 0.3–3 THzTHF - Tremendously High Frequency (ITU band 12, decimillimetre waves)
- 0.3–3 THzHot-electron bolometer (HEB) mixers - heterodyne detection above the superconducting gap
- 0.3–3 THzFree-electron lasers and synchrotron sources in the terahertz rangeFELBE Dresden, TELBE, FELIX Nijmegen, Novosibirsk NovoFEL, and several synchrotrons
- 0.3–3 THzTerahertz pharmaceutical inspection - tablet coating and polymorph screening
- 0.3–3 THzTerahertz standoff detection of explosives and drugs - the promise that mostly failed
Nearby
- 0.275–3 THzNational frequency tables above 275 GHz - what silence means in practice
- 296–300 GHz296-306 GHz passive-protected gap (lower part, 296-300 GHz)
- 296–306 GHz296-306 GHz passive-protected gap (Resolution 731 conditions apply)
- 296–306 GHzEESS/SRS passive identification 296-306 GHz (RR 5.565)
- 0.3–3 THzTerahertz medical imaging - skin cancer margins, burns and dental caries
- 0.3–3 THzRotational spectroscopy line catalogues (JPL and CDMS) - the reference data for this whole slice
- 0.3–3 THzAbsence of any ISM designation above 300 GHz