Cat's Whisker
Industrial Allocation

Electric fence energisers (impulse QRM)

0.01–3 MHz
2.99 MHz wide · Low frequency
Modes
Impulse
Allocation
Reserved
Region
Worldwide
Service
Unintentional broadband impulse radiation

The once-per-second tick that ruins LF and MF reception across rural Australia, New Zealand and anywhere with livestock.

An electric fence energiser dumps a several-kilovolt, few-joule pulse into kilometres of bare wire about once a second. The pulse is broadband and the fence is a superb long-wire antenna, so the result is a sharp click heard from VLF right through HF, often over several kilometres. On a receiver the signature is unmistakable: a regular tick at almost exactly one-second intervals, sometimes several energisers at slightly different rates producing a slow beat. Faults make it far worse - a cracked insulator, a wire touching a fence post or vegetation creates an arc that broadens the noise enormously. It is the single most common interference complaint for rural amateurs in Australia and New Zealand, and it is fixable: the culprit is usually a specific faulty insulator that can be found by walking the fence with a portable AM radio. Blankers in modern SDR software cope with it reasonably well because the pulse is short and periodic.

Inside this band

Nearby

Sources